S-transform and wavelet transform based approach for islanding detection is proposed in distributed generation (DG) based hybrid system. The hybrid system consisting of photovoltaic, fuel cell and wind systems connected to utility grid are considered. The negative sequence voltage signal is used in islanding detection of these resources from the grid. The energy content and standard deviation (SD) of S-transform contour and wavelet transform signal is also reported for the study which clearly reflects the advantages of S-transform in localizing and detecting the islanding events.
机译:在基于分布式发电(DG)的混合系统中,提出了一种基于S变换和小波变换的孤岛检测方法。考虑了由光伏,燃料电池和风力系统组成的混合系统,该系统连接到公用电网。负序电压信号用于从电网孤岛检测这些资源。还报告了S变换轮廓和小波变换信号的能量含量和标准差(SD),这清楚地反映了S变换在定位和检测孤岛事件方面的优势。