摘要

Six laboratories in Japan have performed round-robin test (RRT) on measurement of repetitive PD inception voltage (RPDIV) under well-controlled experimental condition. They used common twisted-pair sample, common impulse generator and common data sheet with normalized air pressure and temperature. Scatterings of data were small except in relative humidity. Stability of PD occurrences against repetitive impulses was investigated using all record of PD data stored in PC. This paper reports the test procedures and the results of the RRT for RPDIV measurement.
机译:日本的六个实验室在控制良好的实验条件下,对重复性PD起始电压(RPDIV)的测量进行了循环测试(RRT)。他们使用了通用的双绞线样品,通用的脉冲发生器和通用的数据表,并标准化了气压和温度。除相对湿度外,数据散布很小。使用存储在PC中的PD数据的所有记录,研究了PD发生对重复冲动的稳定性。本文报告了用于RPDIV测量的RRT的测试程序和结果。