首页> 外文会议>2010 International Conference on Computer, Mechatronics, Control and Electronic Engineering >Experimental study on boiler operating conditions on the efficiency of circulating fluidize bed flue gas desulphurization
【24h】

Experimental study on boiler operating conditions on the efficiency of circulating fluidize bed flue gas desulphurization

机译:锅炉运行条件对循环流化床烟气脱硫效率的实验研究

获取原文

摘要

In order to resolve the problem that changes in boiler operating conditions affecting the efficiency of circulating fluidize bed flue gas desulphurization, we designed and built an experiment table for the study of the operating parameters on desulphurization efficiency. The result is: the best desulphurization tower entrance temperature range of the gas is 117 ∼ 124°C, and the best desulphurization tower exit temperature range of the gas is 74–75°C. Under this temperature, the best water spray is 1.17–1.25m3/h. In this condition, the desulphurization efficiency can reach 90%; the higher desulphurization tower entrance SO2 density is, the harder desulphurization efficiency can be reached; when the inject water is steady, the desulphurization efficiency will decrease by the boiler load increase.
机译:为解决锅炉工况变化影响循环流化床烟气脱硫效率的问题,设计并建立了实验表,研究了脱硫效率的运行参数。结果是:气体的最佳脱硫塔入口温度范围是117〜124°C,气体的最佳脱硫塔出口温度范围是74–75°C。在此温度下,最佳喷水量为1.17–1.25m 3 / h。在这种条件下,脱硫效率可以达到90%;脱硫塔入口SO 2 的密度越高,脱硫效率越高。当注入水稳定时,脱硫效率会随着锅炉负荷的增加而降低。