首页> 外文会议>2010 Conference on Precision Electromagnetic Measurements >A new indirect calibration method for equivalent source mismatch of a power splitter using measurements at only one-port
【24h】

A new indirect calibration method for equivalent source mismatch of a power splitter using measurements at only one-port

机译:一种新的间接校准方法,仅使用一个端口的测量结果即可得出功率分配器等效源不匹配的情况

获取原文

摘要

A new calibration method is described for the equivalent source mismatch (ΓG) of a power splitter. It uses one-port measurements by an ordinary one-port calibration at the test port of a vector network analyzer, with the remaining ports loaded with termination, imperfect load, and a series of three characterized standards, i.e., open, short and load. It also takes advantage of the reciprocity characteristic of the power splitter. As the system impedance is normalized to the impedance of the termination, the termination works as a perfect load in measurements and calculations for the S-parameters of the power splitter.
机译:针对功率分配器的等效源失配(Γ G )描述了一种新的校准方法。它在矢量网络分析仪的测试端口上通过普通的单端口校准使用单端口测量,其余端口加载有端接,不完美的负载以及一系列三个特征性标准,即开路,短路和负载。它还利用了功率分配器的互易特性。由于系统阻抗已根据端子的阻抗进行归一化,因此在功率分配器的S参数的测量和计算中,端子可作为理想的负载。