The failure probability of sensitive equipment due to voltage sag usually depends on the characteristics of voltage sags and the voltage tolerance of equipment, they are both uncertainty. It is difficult to assess and predict equipment failure probability well and truly in practical engineering. The uncertain properties both of voltage sag and equipment tolerance are considered in this paper in order to assess the failure probability of sensitive equipment due to voltage sag. The failure event of equipment caused by voltage sags is considered as a fuzzy-random event and a fuzzy-random variable is used to describe equipment failure event. A fuzzy-random model is developed and ¿-cut sets of the fuzzy-random variables are introduced also. The validity of the proposed method is proved using personal computer and comparing with the results of Monte Carlo simulation.
机译:电压暂降引起的敏感设备的故障概率通常取决于电压暂降的特性和设备的耐压性,两者都是不确定的。在实际工程中很难准确地评估和预测设备故障的可能性。考虑电压暂降和设备容差的不确定性,以评估由于电压暂降导致的敏感设备的故障概率。由电压暂降引起的设备故障事件被认为是模糊随机事件,并且用模糊随机变量来描述设备故障事件。建立了一个模糊随机模型,并引入了模糊随机变量的β-割集。用个人计算机证明了该方法的有效性,并与蒙特卡罗模拟的结果进行了比较。