Air-source heat pump has air as heat source; the system is simple, low initial investment. But the performance of air-source heat pump fluctuates big with the outdoor air temperature changes, especially in the summer hottest and winter coldest day, the cooling thermal capacity and the efficiency will significantly decline. In order to improve the air-source heat pump efficiency and thermal capacity in the summer hottest and winter coldest day, this paper put forward a ground water assistant air source compound heat pump (GWA-ASCHP) and test the cooling performance in rated and peak load conditions. The results show that the performances of GWAASCHP were improved observably by the assistant ground water. When the water flow is 50% of the single ground water source heat pump system, the EER of the GWA-ASCHP is about 30% more than the air-source heat pump in rated condition and the EER can be raised nearly 65% in peak cooling condition.
机译:空气源热泵以空气为热源。该系统操作简单,初期投资低。但是空气源热泵的性能会随着室外空气温度的变化而波动很大,特别是在夏季最热和冬季最冷的日子,制冷热容量和效率将大大下降。为了提高夏季最热和冬季最冷天的气源热泵效率和热容量,提出了一种地下水辅助气源复合热泵(GWA-ASCHP),并在额定和峰值条件下进行了制冷性能测试。负载条件。结果表明,辅助地下水明显改善了GWAASCHP的性能。当水流量为单个地下水源热泵系统的50%时,GWA-ASCHP的EER比额定条件下的空气源热泵多约30%,并且峰值EER可以提高近65%。冷却条件。