Investigation of quantitative polychromatic X-ray phase-contrast tomography for tissue characterization

机译:定量多色X射线相衬断层扫描技术用于组织表征的研究

获取原文

摘要

At diagnostic X-ray energies, variations in the real component of the refractive index of tissues are several orders of magnitude larger than variations in the imaginary component, or equivalently, the X-ray attenuation coefficient. Consequently, X-ray phase-contrast imaging may permit the visualization of tissues that have identical, or very similar, X-ray absorption properties. Quantitative in-line phase-contrast tomography methods seek to reconstruct the three-dimensional (3D) complex X-ray refractive index distribution of tissue. Almost all existing image reconstruction algorithms for quantitative phase-contrast tomography make physical assumptions that are not consistent with benchtop or clinical implementations that employ an X-ray tube. Such assumptions include a monochromatic plane-wave X-ray beam that possesses perfect coherence properties. In this work, we implement and investigate a reconstruction theory for quantitative phase-contrast tomography that is suitable for use with polychromatic X-ray beams produced by a tube source. An image reconstruction algorithm is implemented that requires, as input data, two intensity measurements at each tomographic view that correspond to incident X-ray beams with distinct coherence properties. Computer-simulation studies that emulate polychromatic tube-based imaging conditions are conducted to assess the effectiveness of the reconstruction method for characterizing soft tissue structures.
机译:在诊断X射线能量下,组织折射率的实数分量的变化比虚构分量的变化(或等效地,X射线衰减系数)大几个数量级。因此,X射线相衬成像可以使具有相同或非常相似的X射线吸收特性的组织可视化。定量在线相衬层析成像方法试图重建组织的三维(3D)复杂X射线折射率分布。几乎所有用于定量相差断层扫描的现有图像重建算法都做出与使用X射线管的台式或临床实施方式不一致的物理假设。这样的假设包括具有完美相干特性的单色平面波X射线束。在这项工作中,我们实现并研究了定量相衬层析成像的重建理论,该理论适用于由管源产生的多色X射线束。实现了一种图像重建算法,该算法需要在每个层析成像视图上将两个强度测量作为输入数据,这些强度测量对应于具有不同相干特性的入射X射线束。进行了模拟基于多色管的成像条件的计算机模拟研究,以评估用于表征软组织结构的重建方法的有效性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号