首页> 外文会议>Conference on ultrasonic imaging and signal processing >Frequency Compounding in Multifrequency Vibro-acoustography
【24h】

Frequency Compounding in Multifrequency Vibro-acoustography

机译:多频振动声像图中的频率复合

获取原文

摘要

Vibro-acoustography is a speckle-free ultrasound based imaging modality that can visualize normal and abnormal soft tissue through mapping stimulated acoustic emission. The acoustic emission is generated by focusing two ultrasound beams of slightly different frequencies (Δf= f_1-f_2) to the same spatial location and vibrating the tissue as a result of ultrasound radiation force. Reverberation of the acoustic emission can create dark and bright areas in the image that affect overall image contrast and detectability of abnormal tissue. Using finite length tonebursts yields acoustic emission at Δf and at sidebands centered about Δf that originate from the temporal toneburst gating. Separate images are formed by bandpass filtering the acoustic emission at Δf and the associated sidebands. The data at these multiple frequencies are compounded through coherent or incoherent processes to reduce the artifacts associated with reverberation of the acoustic emission. Experimental results from a urethane breast phantom and in vivo human breast scans are shown. The reduction in reverberation artifacts are analyzed using a smoothness metric which uses the variances of the gray levels of the original images and those formed through coherent and incoherent compounding of image data. This smoothness metric is minimized when the overall image background is smooth while image features are still preserved. The smoothness metric indicates that the images improved by factors from 1.23-4.33 and 1.09-2.68 in phantom and in vivo studies, respectively. The coherent and incoherent compounding of multifrequency data demonstrate, both qualitatively and quantitatively, the efficacy of this method for reduction of reverberation artifacts.
机译:振动声学成像是一种基于超声的无斑点成像方式,可以通过绘制受刺激的声发射图来可视化正常和异常的软组织。通过将频率略有不同的两个超声波束(Δf= f_1-f_2)聚焦到相同的空间位置并通过超声辐射力使组织振动来产生声发射。声发射的混响会在图像中产生暗区和亮区,从而影响整体图像对比度和异常组织的可检测性。使用有限长度的音爆产生了在Δf和以Δf为中心的边带处的声发射,这些噪声源于时间音爆选通。通过对Δf处的声发射和相关的边带进行带通滤波,可以形成单独的图像。通过相干或非相干过程对这些多个频率处的数据进行复合,以减少与声发射混响相关的伪像。显示了来自氨基甲酸乙酯乳房体模和体内人类乳房扫描的实验结果。使用平滑度度量分析混响伪影的减少,该度量度使用原始图像的灰度级的变化以及通过图像数据的相干和不相干合成而形成的灰度级的变化。当整个图像背景是平滑的同时仍保留图像特征时,此平滑度指标将降至最低。平滑度指标表明,在幻像和体内研究中,图像分别改善了1.23-4.33和1.09-2.68的因子。多频数据的相干和不相干复合在定性和定量方面证明了该方法减少混响伪影的功效。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号