DIGMEO37MV is the thrust wear detector of turbine. On 12th, May, before the turbine ran up, the value of this channel often fluctuated. The engineer checked the channel, terminal, continuity, insulation, and driver and so on, no problem finds. At last, when disconnected the end of the detector from the driver, then re-connected the end to the driver, the channel value is OK, after a while it became wrong again. Measured the resistance of the detector, it is 13Ohm when the channel is OK, and 76 Ohm when the channel is wrong. According to the result of the checked, the conclusion is the character of the detector had changed. Both the measured value GME037MV and GME038MV are high (0. 7mm), the turbine will trip, In the end the detector of GME037MV was replaced when the unit shut down.
机译:DIGMEO37MV是涡轮机的推力磨损检测器。 5月12日,在涡轮机运转之前,该通道的值通常会波动。工程师检查了通道,端子,通断性,绝缘性和驱动器等,没有发现任何问题。最后,当将检测器的端部与驱动器断开连接,然后将端部与驱动器重新连接时,通道值正常,过一会儿又变得错误了。测量检测器的电阻,当通道正常时为13Ohm,当通道错误时为76Ohm。根据检查结果,得出的结论是检测器的特性发生了变化。 GME037MV和GME038MV的测量值都很高(0. 7mm),涡轮将跳闸。最后,当设备关闭时,更换了GME037MV的检测器。