Effect of three different fresh air modes on the indoor pollutant dispersion is analyzed by the method of CFD (Computational Fluid Dynamics) simulation and experiment. The fresh air modes include natural ventilation, hybrid ventilation and mechanical ventilation with total heat exchanger. Performance of the fresh air modes is compared considering the factors like fresh air volume, heat/cold load and outdoor air parameters etc. In addition, the ventilation performance under different fresh air volume and control modes is contrastively studied under running condition. The result shows that, fresh air volume is the key factor in diluting the pollutant and heat recovery is vital for energy efficiency.
机译:通过CFD(计算流体动力学)模拟和实验方法,分析了三种不同的新鲜空气模式对室内污染物扩散的影响。新鲜空气模式包括自然通风,混合通风和带总热交换器的机械通风。比较了新鲜空气模式的性能,并考虑了新鲜空气量,热/冷负荷和室外空气参数等因素。此外,对比研究了在运行条件下不同新鲜空气量和控制模式下的通风性能。结果表明,新鲜空气量是稀释污染物的关键因素,而热量回收对于提高能源效率至关重要。