Temperature of urban sewage is suitable, but its flux is insufficient as cooling and heating source. So in many cases the conventional sewage source heat pump system is unable to satisfy the building heat peak load. According to this condition, a novel mentality is proposed about which the freezing latent heat of urban sewage is used as the low temperature heat source of heat pump in the building as well as sensible heat. Then the important equipment is developed, freezing latent heat exchanger namely, which can eliminate the ice safely, extract the heat continuously, remove the sewage soft-dirt, and strengthen heat transfer. According to the sewage characteristics, reasonable form of the urban sewage source heat pump with freezing latent heat collection is discussed and established. The results of analysis show that the new system has broad feasibility and giant application potential.
机译:城市污水温度适宜,但其通量不足作为冷热源。因此,在许多情况下,传统的污水源热泵系统无法满足建筑物的热峰值负荷。根据这种情况,提出了一种新的思路,即城市污水的冷冻潜热被用作建筑物中热泵的低温热源。然后研制出重要的设备,即冷冻潜热换热器,它可以安全地除冰,连续地吸热,去除污水中的软污物,并加强传热。根据污水的特性,讨论并建立了具有潜热潜能的城市污水源热泵的合理形式。分析结果表明,该新系统具有广阔的可行性和巨大的应用潜力。