首页> 外文会议>Energy and Environment Technology, 2009. ICEET '09 >The Energy-Saving Design Practices for Direct Cooling Refrigerator
【24h】

The Energy-Saving Design Practices for Direct Cooling Refrigerator

机译:直冷式冰箱的节能设计实践

获取原文

摘要

The area of evaporator on cold storage chamber was added under a constant total evaporator area. Composite and stereoscopic structure with laminated exchanger flake was used on evaporator of freezing chamber. Wing - flakes were fixed outside the refrigerant pipe coil with a S-type to increase the refrigeration capacity of the top part and the bottom part of freezing chamber. The refrigeration cycle of double path was adopted on project study. By the optimizing design of the condenser structure and circling - gas exchanger , direction and position of anti - condensation pipe and evaporator pipe, by matching the load of compressor, condenser and evaporator , a new type of direct cooling refrigerator was recently developed. It consumes 0.39 kWh per day under the maximum load.
机译:在恒定的总蒸发器面积下添加冷藏室上的蒸发器面积。在冷冻室的蒸发器上使用了具有叠层交换器薄片的复合和立体结构。翼形薄片以S型固定在制冷剂管盘管的外部,以增加冷冻室顶部和底部的制冷量。在项目研究中采用了双路制冷循环。通过冷凝器结构和循环气体交换器,防冷凝管和蒸发器管的方向和位置的优化设计,通过匹配压缩机,冷凝器和蒸发器的负载,最近开发了一种新型的直冷式制冷机。在最大负载下,它每天消耗0.39 kWh。