Patients admitted to the Intensive Cardiac Care Unit are closely monitored by different devices that generate alarms when an abnormality is detected. However, most alarms do not signify a life-threatening event. During a four month period 34,827 alarms were collected electronically. The most frequent alarm categories were related to mechanical ventilation (42.2%), blood pressure (32.3%), electrocardiogram (9.8%) and heart rate (8.1%). 2750 (7.9%) of the alarms were not related to limit violations, but were technical advisories. Overall alarm frequency was 2.2 per patient per hour. However, the distribution over time varied greatly and alarm ¿bursts¿ were seen when blood samples were taken and patients were woken. Reduction in alarms could be achieved by reducing overuse of monitoring parameters, utilizing patient specific limits and combining alarms within the ¿bursts¿.
机译:重症监护病房收治的患者受到不同设备的密切监视,这些设备会在检测到异常时发出警报。但是,大多数警报并不表示威胁生命的事件。在四个月的时间里,通过电子方式收集了34,827条警报。最常见的警报类别与机械通气(42.2%),血压(32.3%),心电图(9.8%)和心率(8.1%)有关。 2750个(7.9%)警报与违反限值无关,但属于技术建议。总体警报频率为每名患者每小时2.2。但是,随着时间的流逝变化很大,并且在采集血液样本和唤醒患者时看到了警报“突发”。通过减少对监测参数的过度使用,利用患者的特定限制并在,burstsÂÂ范围内组合警报,可以减少警报。