首页> 外文会议>Research and Development (SCOReD), 2009 >Comparison of the experimental results of a newly developed interfacing method on a Single-phase Matrix Converter employing safe commutation strategy
【24h】

Comparison of the experimental results of a newly developed interfacing method on a Single-phase Matrix Converter employing safe commutation strategy

机译:使用安全换相策略的单相矩阵转换器上新开发的接口方法的实验结果比较

获取原文

摘要

The aim of this paper is to compare the experimental result of Single-phase Matrix Converter (SPMC) employing safe commutation strategy to the simulation of the SPMC using MATLAB/Simulink. A test rig of SPMC with safe commutation had been developed and its outputs (in terms of voltage and current) are monitored through an oscilloscope. One method is by recording the waveform on the oscilloscope onto a storage device and then processing it by propriety software. The method developed here is by connecting the oscilloscope to a PC via a LabVIEW interface. The advantages of the developed method are its ability to be processed without the hassle of external aid and ability to record a very much longer data length that is not limited to the capability of the storage of the oscilloscope.
机译:本文的目的是比较采用安全换相策略的单相矩阵变换器(SPMC)的实验结果与使用MATLAB / Simulink进行SPMC仿真的结果。已经开发出具有安全换相的SPMC测试设备,并通过示波器监视其输出(就电压和​​电流而言)。一种方法是将示波器上的波形记录到存储设备上,然后通过适当的软件对其进行处理。此处开发的方法是通过LabVIEW接口将示波器连接到PC。所开发方法的优点是无需外部帮助即可进行处理的能力,以及记录非常长的数据长度的能力,而这不限于示波器的存储能力。