首页> 外文会议>Ultrasonics Symposium (IUS), 2009 >Thermal ablation of liver tumors by high-intensity-focused ultrasound using a toroid transducer. Results of animal experiments
【24h】

Thermal ablation of liver tumors by high-intensity-focused ultrasound using a toroid transducer. Results of animal experiments

机译:使用环形换能器通过高强度聚焦超声对肝脏肿瘤进行热消融。动物实验结果

获取原文

摘要

The aim of this study was to demonstrate in a rabbit liver tumor model that high intensity focused ultrasound (HIFU) produced with toroidal-shaped emitters may have a role in treating colorectal liver metastases. The HIFU device was composed of eight ultrasound emitters created by sectioning a single toroidal piezocomposite transducer. Each of the eight emitters was divided into 32 transducers operating at a frequency of 3 MHz. The toroidal transducer has a diameter of 70 mm and a radius of curvature of 70 mm. A 7.5 MHz ultrasound imaging probe (Vermon, Tours, France) was placed in the centre of the device. Using this transducer single lesions of 7 cm3 were created in 40 seconds. Juxtaposition of single lesions was performed under ultrasound guidance. VX2 tumor segments (25 mg) were implanted into right lateral liver lobes of 45 New Zealand white rabbits. Fifteen rabbits were treated with toroidal HIFU ablation (Group 1). Fifteen rabbits were resected (Group 2). Fifteen rabbits were not treated and formed a control group (Group 3). Group 1 and 3 were compared to evaluate treatment efficacy. Group 1 and 2 were compared to evaluate if the toroidal HIFU treatment increases the risk of tumor dissemination. Total hepatectomy took place 11 days after treatment. The therapeutic response was evaluated with follow-up ultrasound imaging and the corresponding gross pathology and histology. HIFU ablation produced using the toroidal transducer allowed fast and homogeneous tumor treatments. Ablations were visible on sonograms. The VX2 tumors were completely coagulated and were surrounded by ablated liver tissue without secondary thermal lesions in surrounding organs. In the control group tumor volume was 225% higher at the time of autopsy when compared to the volume at the day of the treatment. Tumor dissemination was lower in the HIFU group (25%) compared with resected (67%) and control (38%) groups. Findings of ultrasound imaging, gross pathology and histology suppor-ted these outcomes. Successful rabbit liver tumor ablation can be achieved using a toroidal HIFU transducer under ultrasound imaging guidance and therefore could be an effective treatment of localized tumors. There was no complication related to the HIFU procedure. Its clinical usefulness has to be further proven.
机译:这项研究的目的是在兔肝肿瘤模型中证明用环形发射器产生的高强度聚焦超声(HIFU)可能在治疗结直肠肝转移中起作用。 HIFU设备由八个超声发射器组成,这些超声发射器是通过切开单个环形压电复合换能器而制成的。八个发射器中的每一个都分为32个以3 MHz的频率运行的换能器。环形换能器的直径为70毫米,曲率半径为70毫米。将7.5 MHz超声成像探头(Vermon,法国图尔)放置在设备的中央。使用该换能器在40秒内产生了7 cm 3 的单个病变。在超声引导下进行单个病变的并置。将VX2肿瘤片段(25 mg)植入45只新西兰白兔的右侧肝叶中。用环形HIFU消融治疗了15只兔子(组1)。切除15只兔子(第2组)。未治疗的兔子为15只,并形成对照组(第3组)。比较第1组和第3组以评估治疗效果。比较第1组和第2组以评估环形HIFU治疗是否增加了肿瘤扩散的风险。治疗后11天进行了全肝切除术。通过后续的超声成像以及相应的总体病理学和组织学评估治疗反应。使用环形换能器产生的HIFU消融术可以实现快速,均匀的肿瘤治疗。超声检查可见消融。 VX2肿瘤已完全凝固,被消融的肝组织包围,周围器官无继发性热损伤。在对照组中,与治疗当天的肿瘤体积相比,尸体解剖时的肿瘤体积高出225%。 HIFU组(25%)的肿瘤扩散率低于切除组(67%)和对照组(38%)。超声成像,大体病理学和组织学检查结果支持 这些结果。在超声成像指导下使用环形HIFU换能器可成功实现兔肝肿瘤消融,因此可能是局部肿瘤的有效治疗方法。没有与HIFU手术相关的并发症。它的临床用途有待进一步证明。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号