首页> 外文会议>The 2008 International Symposium on Safety Science and Technology(2008年安全科学技术国际会议)论文集 >Study on Leak Detecting Sensors Placement for Storage Tank Farm Safety Monitoring and Controlling System
【24h】

Study on Leak Detecting Sensors Placement for Storage Tank Farm Safety Monitoring and Controlling System

机译:储罐场安全监控系统检漏传感器的布置研究

获取原文

摘要

The placement of leak detecting sensors plays an important role in early warning and prevention of fire, explosion and poisoning accidents in storage tank farm. However, up to now there have been no quantitative evaluation criteria, and the placement of detecting nodes is mainly determined by roughly designed experiments or practical experience. This paper studies the setup of leak detecting sensors on the base of statistical analysis of equipment malfunction and leak accidents of storage tank farm, introduces the continuous leak theory to calculate and analyze the concentration distribution of typical leakage, and by combing the engineering practical experiences and detecting meters' performance investigation like sensitivity and response time, proposes optimized placement principles and density of the leak detecting sensors on storage tank farm.
机译:泄漏检测传感器的布置在预警和预防储罐区火灾,爆炸和中毒事故中发挥着重要作用。但是,到目前为止,还没有定量评估标准,检测节点的位置主要由粗略设计的实验或实践经验确定。本文在对储罐场设备故障和泄漏事故进行统计分析的基础上,对泄漏检测传感器的设置进行了研究,介绍了连续泄漏理论,对典型泄漏的浓度分布进行了计算和分析,并结合工程实际经验和实践经验,对泄漏检测进行了分析。检测仪表的性能调查(例如灵敏度和响应时间),提出了存储罐场中泄漏检测传感器的优化放置原理和密度。

著录项