Experiments were conducted to investigate the technology and mechanism of homogenous C1O2/Mn(II)system catalytic Oxidation of phenol-containing wastewater under microwave irradiation.The relationships between removal percentage and catalyst dosage,microwave power,contact time and pH were irregular.The research suggested that the optimum conditions for phenol removal percentage approaching 90.39%were as follows:the oxidant dosage was 80mg/L,the contact time was 5min,microwave power was 50W and the solution pH was in the range of 3~10.Under the same experimental conditions,the COD removal percentage cloud come up to 79.13%.Comparing with traditional process,we can conclude that rmcrowave in this process not only is a heating source but also induce the non-thermal efficiency.
机译:进行了实验研究微波辐射下均相C1O2 / Mn(II)体系催化氧化含酚废水的机理和技术,去除率与催化剂用量,微波功率,接触时间和pH值之间的关系是不规则的。提出了达到90.39%的最佳脱酚率条件:氧化剂用量为80mg / L,接触时间为5min,微波功率为50W,溶液pH为3〜10。在实验条件下,COD去除率达到了79.13%。与传统工艺相比,可以认为微波在此过程中不仅是热源,而且会引起非热效率。