【24h】

Experimental study on emergency treatment of source water accidentally polluted by heavy metals

机译:重金属污染源水应急处理试验研究

获取原文

摘要

An experimental study is carried out on emergency treatment of source water that accidentallypolluted by Cr(VI)and Cd.The methods of using ferrous sulfate for Cr(VI)removal and increasing pH value of source water or adding sodium carbonate for Cd removal are proposed respectively.based on the evaluation of the removal effects by current treatment process.When Cr(VI)concentration in source water is 0.10-2.00 mg/L,the corresponding dosage of ferrous sulfate is 3.0-16.0 mg/t,and the toNal amount of Cr(VI)in treated water is decreased below 0.02mg/L.It is proved that the removal rate of Cd can reach 90.0%when the pH value of source water is 9.0.Adding sodium carbonate can not only change pH value of water,but also promote the production of cadmium carbonate and cadmium’hydroxide.which enhance Cd removal effect to some degree.
机译:开展了对Cr(VI)和Cd意外污染的原水进行应急处理的实验研究。提出了利用硫酸亚铁去除Cr(VI),提高原水pH值或添加碳酸钠去除Cd的方法。根据目前处理工艺的去除效果评估。当源水中的Cr(VI)浓度为0.10-2.00 mg / L时,相应的硫酸亚铁剂量为3.0-16.0 mg / t,总纳尔处理水中Cr(VI)的含量降低到0.02mg / L以下。证明了当源水的pH值为9.0时,Cd的去除率可达到90.0%。添加碳酸钠不仅可以改变水的pH值,还促进了碳酸镉和氢氧化镉的产生。在一定程度上提高了Cd的去除效果。