首页> 外文会议>Corrosion 2008;Corrosion conference and expo >5,000 KM ROW CP SURVEY ANALYSIS AND THE POTENTIAL ADVANTAGES OF THE - 100 MV POLARIZATION CRITERION FOR THE CP OF AGED COATING OIL AND GAS PIPELINES IN GULF AND NORTH OF MEXICO
【24h】

5,000 KM ROW CP SURVEY ANALYSIS AND THE POTENTIAL ADVANTAGES OF THE - 100 MV POLARIZATION CRITERION FOR THE CP OF AGED COATING OIL AND GAS PIPELINES IN GULF AND NORTH OF MEXICO

机译:墨西哥湾北部和北部的老化涂层油和天然气管道CP的5,000 KM ROW CP调查分析和-100 MV极化判据的潜在优势

获取原文

摘要

A survey of over 5,000 Km of pipelines was developed in 2006 to assess the CP performance of the pipelines located in the main ROWs of the Mexican States of Veracruz, Tamaulipas, Nuevo Leon, Coahuila, Durango, y Chihuahua. Historically the CP surveying in the region has been done measuring the ON potentials and applying the -850 mV criterion to these measurements. By employing a set of several satellite synchronized by GPS instrumentation, the instant OFF potentials presently reported resulted considerably more electropositive, and the compliance to the -850 mV criterion was found under 50%, in a set of over 5,000 measurements in this important region of Mexico. Besides the needs of new CP infrastructure, we report the main causes that impair the compliance of the CP to the -850 mV criterion of the NACE RP 0169 - 2002. Among these are the problems of isolation of the pipelines to main processing units such as refineries, pumping or metering stations. Findings of irregular, non instrumented or even controlled electrical interconnections between the pipelines in production or abandoned, were also pointed out as major causes for the insufficient CP. Old and damaged coatings of pipelines with many years in service contribute tu limit the CP compliance to codes. Out of service and poorly coated pipelines were found sharing the CP systems in the ROWs, with very deleterious effect on the overall CP performance due to the elevated current demand of abandoned pipelines lacking coating maintenance. In the present scenario a remarkable effort is to be made to pursue the electrical isolation of the pipelines, the needed coating reparations, as well as the use of the 100 mV potential criterion was concluded to be a sound approach to maximize the pipeline operational compliance to the integrity management programs in the Gulf and North of Mexico.
机译:2006年,对5,000多公里的管道进行了调查,以评估位于墨西哥韦拉克鲁斯州,塔毛利帕斯州,新莱昂州,科阿韦拉,杜兰戈州和奇瓦瓦州的墨西哥主要州的管道的CP性能。从历史上看,该地区的CP测量是通过测量ON电位并将-850 mV准则应用于这些测量来完成的。通过使用一组由GPS仪器同步的几颗卫星,目前报道的瞬时OFF电位产生了更大的正电,在这一重要区域的5,000多次测量中,发现符合-850 mV标准的比例低于50%。墨西哥。除了新的CP基础设施的需求之外,我们还报告了破坏CP符合NACE RP 0169-2002的-850 mV标准的主要原因。其中包括隔离通往主处理单元的管道的问题,例如炼油厂,泵站或计量站。还指出,在生产中或废弃的管道之间发现不规则的,非仪器化的或什至受控的电气互连,这是造成阴极保护不足的主要原因。服役多年的管道的旧旧破损涂层将CP的合规性限制在规范范围内。发现停运和涂膜不良的管道在ROW中共享CP系统,由于废弃管道缺乏涂层维护而对电流的需求增加,这对整体CP性能产生了非常有害的影响。在目前的情况下,将做出巨大的努力来实现管道的电气隔离,所需的涂层修复以及使用100 mV电位标准的结论,这是使管道运行达标最大化的合理方法。墨西哥湾和墨西哥北部的完整性管理计划。

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号