CanariCam is the facility multi-mode mid-IR camera developed by the University of Florida (UF) for the 10.4-meter Gran Telescopio Canarias (GTC). CanariCam contains a 320 × 240-pixel Raytheon array, which will Nyquist-sample the diffraction-limited point-spread-function at wavelengths longer than 8 microns, yielding a field of view of 26"×l9". In Aug. 2007, the University of Florida instrument team held a successful Acceptance Testing (AT) of CanariCam. We describe key performance requirements, and compare these to the actual performance during formal AT. Among the results considered are detector noise characteristics, image quality, and throughput. We focus particularly on the unique dual-beam polarimetric modes. We have demonstrated that with a half-wave plate, it achieves or exceeds the design goals for imaging both polarization planes simultaneously.
机译:CanariCam是佛罗里达大学(UF)为10.4米大加那利群岛(GTC)开发的设施型多模式中红外摄像机。 CanariCam包含一个320×240像素的Raytheon阵列,该阵列将对奈奎斯特采样波长大于8微米的衍射极限点扩展函数进行采样,从而产生26“×19”的视场。 2007年8月,佛罗里达大学仪器团队成功举行了CanariCam的验收测试(AT)。我们描述了关键性能要求,并将其与正式AT期间的实际性能进行比较。考虑的结果包括检测器噪声特性,图像质量和吞吐量。我们特别关注独特的双光束偏振模式。我们已经证明,使用半波片,它可以达到或超过同时对两个偏振面成像的设计目标。