首页> 外文会议>Future Power Systems, 2005 International Conference on >DC-Link Capacitors Sizing for Three-Level Neutral-Point-Clamped Inverters in Four-Wire Distributed Generation Systems
【24h】

DC-Link Capacitors Sizing for Three-Level Neutral-Point-Clamped Inverters in Four-Wire Distributed Generation Systems

机译:四线分布式发电系统中用于三电平中性点钳位逆变器的直流链路电容器的尺寸

获取原文

摘要

When a three-level inverter is used in three-phase four-wire systems, the problem of mid-point voltage variation becomes significant because of the existence of balanced and unbalanced loads. Therefore sizing of the dc-link capacitors with respect to mid-point voltage variation should be studied. This paper presents an analytical study of dc-link capacitors sizing when using a three-level NPC inverter in four-wire systems, where positive, negative and zero sequence load currents are separately analyzed. The calculation of dc-link mid-point currents, mid-point voltage ripples and capacitor sizes are all mathematically derived. Result of this study on one hand establishes the calculation of DC-link capacitor sizes of a three-level NPC inverter when the load characteristics are known. On the other hand, it can be used to analyze the trade-off between using larger dc-link capacitors, and using an additional balancing circuit.
机译:当三级逆变器用于三相四线系统时,由于存在平衡和不平衡的负载,中点电压变化的问题变得显着。因此,应该研究DC-LINK电容器的尺寸相对于中点电压变化。本文介绍了在四线系统中使用三级NPC逆变器时DC-Link电容器尺寸的分析研究,其中分别分析正,负和零序列负载电流。 DC链路中点电流,中点电压纹波和电容器尺寸的计算都是在数学派生的。这项研究的结果一方面建立了当载荷特性已知时三级NPC逆变器的直流链路电容器尺寸的计算。另一方面,它可以用于分析使用较大的直流链路电容器之间的折衷,并使用额外的平衡电路。

著录项