In this paper, we used a new kind of screwy platen superheater to reduce the velocity deviation of tangentially fired boiler horizontal gas pass. The screwy platen superheater was twisted a angle about 45°. Through an experiment, the velocity deviation of tangentially fired boiler horizontal gas pass was reduced about 65% using the screwy platen superheater in a model boiler. Meanwhile it had been detected that by using the screwy SH panels the velocity distribution in front of each heat exchanger in horizontal gas pass was more homogeneous than that of a common straight platen superheater . Test expressed that the screwy platen superheater is very useful to reduce the velocity deviation of tangentially fired boiler horizontal gas pass and this way is first to be used.
机译:在本文中,我们使用了一种新型的螺旋板式过热器来减小切向燃烧锅炉水平气体通道的速度偏差。将螺旋压板过热器扭转大约45°的角度。通过实验,在模型锅炉中使用螺旋压板过热器,切向燃烧锅炉水平气体通过的速度偏差降低了约65%。同时还发现,通过使用螺旋SH板,水平气体通道中每个换热器前面的速度分布比普通直板过热器更均匀。试验表明,螺旋板式过热器对于减小切向燃烧锅炉水平气体通过的速度偏差非常有用,这种方法首先被采用。