首页> 外文会议>Review of Progress in Quantitative Nondestructive Evaluation >THE DEVELOPMENT OF SHEAR AND COMPRESSION ELASTIC MODULI IN CURING EPOXY ADHESIVES MEASURED USING NON-CONTACT ULTRASONIC TRANSDUCERS
【24h】

THE DEVELOPMENT OF SHEAR AND COMPRESSION ELASTIC MODULI IN CURING EPOXY ADHESIVES MEASURED USING NON-CONTACT ULTRASONIC TRANSDUCERS

机译:使用非接触式超声传感器测量环氧胶的剪切和压缩弹性模量的开发

获取原文
获取外文期刊封面目录资料

摘要

Thin epoxy resin adhesive samples were ultrasonically measured using normal incidence radially polarised shear wave ElectroMagnetic Acoustic Transducers (EMATs) that also generate a significant compression wave. This allows us to make simultaneous measurement of the shear and compression wave propagation through the polymer, although the signal to noise ratio is significantly higher for the shear wave measurements. The adhesive thickness examined in the experiments was 1mm, which was chosen to be the optimum thickness for experimental measurement using our apparatus. The epoxy resin systems ('rapid' cure and a 'standard' cure time) described in this paper were supplied in a 2-part cartridge form, mixed by through a special nozzle. Although the number of samples investigated at this stage is small, there does appear to be a fundamental difference in the way in which the elastic moduli develop as cure rate is increased.
机译:使用法向入射径向极化剪切波电磁声换能器(EMAT)超声波测量薄的环氧树脂粘合剂样品,该换能器也会产生明显的压缩波。这使我们能够同时测量剪切波和压缩波在聚合物中的传播,尽管剪切波测量的信噪比明显更高。在实验中检查的粘合剂厚度为1mm,这被选择为使用我们的设备进行实验测量的最佳厚度。本文所述的环氧树脂体系(“快速”固化和“标准”固化时间)以两部分装的形式提供,并通过专用喷嘴进行混合。尽管在此阶段研究的样品数量很少,但随着固化速率的提高,弹性模量的发展方式确实存在根本差异。