首页> 外文会议>Environmental Electromagnetics, 2003. CEEM 2003. Proceedings. Asia-Pacific Conference on >Estimation of the EMP response of a system from its continuous wave measurement results
【24h】

Estimation of the EMP response of a system from its continuous wave measurement results

机译:从连续波测量结果估算系统的EMP响应

获取原文

摘要

Traditionally, the electromagnetic protection ability of a system, such as filters, shielding enclosures, etc., is measured in the frequency-domain and expressed as insertion loss or shielding effectiveness. When the time-domain characteristics of the system are required to evaluate their pulse response, time-domain tests need to be conducted. However, it may not be convenient to carried out time-domain tests because of the availability of test facilities. Theoretically, suppose the system works in a linear range, its pulse response can be estimated from frequency-domain measured data. We evaluated this concept by experiments. A digital filter model of the system under test is used to approximate the measured frequency response and then employed to calculate the output of the system under pulsed input. The estimated pulse responses are compared with measured ones. Results show that it is possible to estimate approximately the magnitude and shape of the time-domain response by this approach.
机译:传统上,系统(例如滤波器,屏蔽罩等)的电磁保护能力是在频域中测量的,并表示为插入损耗或屏蔽效果。当需要系统的时域特性来评估其脉冲响应时,需要进行时域测试。但是,由于测试工具的可用性,进行时域测试可能并不方便。从理论上讲,假设系统在线性范围内工作,则可以从频域测量数据估计其脉冲响应。我们通过实验评估了这个概念。被测系统的数字滤波器模型用于近似测得的频率响应,然后用于计算脉冲输入下系统的输出。将估计的脉冲响应与测量的脉冲响应进行比较。结果表明,通过这种方法可以估计时域响应的大小和形状。

著录项