首页> 外文会议>Water Chemistry of Nuclear Reactor Systems 8 >Corrosion Monitoring in Chemical Cleaning of Steam Generator
【24h】

Corrosion Monitoring in Chemical Cleaning of Steam Generator

机译:蒸汽发生器化学清洗中的腐蚀监测

获取原文

摘要

Corrosion monitoring may be required during chemical cleaning of nuclear steam generators. Continuous corrosion measurement can be obtained with electrochemical techniques, in particular linear polarization technique by using commercially available instrument. To determine the reliability of linear polarization in chemical cleaning solutions, Linear polarization and weight loss of A_3 carbon steel and S_(271) steel were studied in solution C and solution D. The real Tafel slopes of A_3 carbon steel and S_(271) steel were measured Tafel slopes that instrument had set up were approximate to the real Tafel slopes. We had carried out engineering experiment. With few exceptions, most data between linear polarization and weight loss are similar. Results of the work indicate that liner polarization can be used in monitoring corrosion rate during chemical cleanings of nuclear steam generator.
机译:在化学清洁核蒸汽发生器过程中可能需要腐蚀监测。可以使用电化学技术,特别是线性极化技术,通过使用可商购的仪器获得连续的腐蚀测量值。为了确定化学清洗溶液中线性极化的可靠性,在溶液C和溶液D中研究了A_3碳钢和S_(271)钢的线性极化和失重。A_3碳钢和S_(271)钢的实际塔菲尔斜率测量仪器建立的塔菲尔斜率与真实塔菲尔斜率近似。我们进行了工程实验。除极少数情况外,线性极化和重量损失之间的大多数数据都相似。工作结果表明,衬套极化可用于监测核蒸汽发生器化学清洗过程中的腐蚀速率。