首页> 外文会议>Structural Engineering, Mechanics and Computation >DAMAGE ASSESSMENT OF CORRODED REINFORCED CONCRETE BEAMS USING MODAL TESTING
【24h】

DAMAGE ASSESSMENT OF CORRODED REINFORCED CONCRETE BEAMS USING MODAL TESTING

机译:模态测试对锈蚀钢筋混凝土梁的损伤评估

获取原文

摘要

A laboratory investigation to study the effect of general corrosion on the modal parameters of reinforced concrete beams was conducted. Full scale beams were subjected to reinforcement corrosion until an appreciable amount of steel corrosion damage was introduced using an accelerated technique namely galvanostatic method. The states of damage in the test beams were assessed through measurement of crack width, loss of area and half-cell potential. Modal tests were performed on the test beams after corrosion damage and the modal parameters extracted were compared against that from control beams. The results obtained showed changes in the modal parameters especially natural frequencies and mode shapes. The intensity of the drop in the measured natural frequencies was sensitive to the deterioration state of the beams. Hence, changes in natural frequencies could be established as a damage indicator, which relate to the loss in flexural stiffness of the corroded beams. Using modal assurance techniques to perform orthogonality checks on sets of mode shape from the control and corroded beams, changes could be visualised which were dependant on the degree of corrosion damage induced. Finally, the load carrying capacity of the beams were determined through static load test and the results were correlated with the state of corrosion damage and changes in the modal parameters. This investigation provided further insight on the use of modal parameters to detect and assess damage in structural concrete elements, which can be useful for structural appraisal purposes when applied to full scale structures.
机译:进行了实验室研究,以研究一般腐蚀对钢筋混凝土梁的模态参数的影响。使用加速技术,即恒电流法,对满刻度梁进行钢筋腐蚀,直到引入相当数量的钢腐蚀破坏为止。通过测量裂纹宽度,面积损失和半电池电位来评估测试梁的损坏状态。在腐蚀损伤后对测试梁进行模态测试,并将提取的模态参数与控制梁的模态参数进行比较。获得的结果表明模态参数的变化,尤其是固有频率和模态形状。所测量的固有频率的下降强度对光束的劣化状态敏感。因此,可以将固有频率的变化建立为损伤指标,这与腐蚀梁的抗弯刚度损失有关。使用模态保证技术对来自控制束和腐蚀束的模态形状组进行正交检查,可以看到变化,这取决于引起的腐蚀破坏的程度。最后,通过静载荷试验确定了梁的承载能力,并将结果与​​腐蚀破坏状态和模态参数的变化相关联。这项研究为模态参数的使用提供了进一步的见解,以检测和评估结构混凝土构件中的损伤,当将其应用于全尺寸结构时,对于结构评估而言可能是有用的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号