This 20-year test program evaluates the short- and long-term corrosion interaction between a soft aggressive water supply and thin-wall stainless steel and copper pipe, painted ductile iron, and various coupling techniques (mechanical joints and welded joints) in both primary building supply water service and fire standpipe service (stagnant conditions). Pipe and coupling samples will be removed periodically over the 20-year period; at the end of the service period, the test stand will be disassembled and evaluated. Evaluation techniques will include surface analyses, scanning electron studies, and energy dispersive spectroscopy in addition to visual examination. Water analyses and standard weight-loss corrosion coupons will be used to evaluate the changes.
机译:这项为期20年的测试计划评估了软质侵蚀性供水与薄壁不锈钢和铜管,涂有球墨铸铁之间的短期和长期腐蚀相互作用,以及两种方法中的各种耦合技术(机械接头和焊接接头)建筑物供水服务和消防竖管服务(停滞状态)。管道和连接器样品将在20年内定期清除;在服务周期结束时,将对测试台进行拆卸和评估。除视觉检查外,评估技术还将包括表面分析,扫描电子研究和能量色散光谱学。水分析和标准的减重腐蚀试样将用于评估变化。