首页> 外文会议>Advances in Cryogenic Engineering Materials >THERMAL CONDUCTIVITY OF 34-700 CARBON FIBER COMPOSITES AT CRYOGENIC TEMPERATURES
【24h】

THERMAL CONDUCTIVITY OF 34-700 CARBON FIBER COMPOSITES AT CRYOGENIC TEMPERATURES

机译:低温下34-700碳纤维复合材料的热导率

获取原文

摘要

A steady-state test rig for measuring the thermal conductivity of thin carbon fiber composites at cryogenic temperatures has been constructed and calibrated using a 304 stainless steel sample. Thermal conductivity measurements were carried out on both unidirectional and multi-directional 34-700 carbon fiber-NCT 301 epoxy composite samples from 8 K up to 150 K using the test rig. Thermal diffusivity measurements were made at 295 K and were then used to calculate the thermal conductivity. Unidirectional samples with fibers oriented at 0, 90, and 45 degrees to the direction of heat flow have been evaluated. The thermal conductivity of a sample with laminate plys in the configuration +-45/90/0(3)/90/+-45 has also been measured. At room temperature, the thermal conductivity in the 0° direction is 7 times that in the 90° direction. For the multidirectional sample, the thermal conductivity ranges from 0.22 W/(m·K) at 5.7 K to 2.98 W/(m·K). The general trend of the data is similar to that of the T-300 carbon fiber samples.
机译:已经建立了用于测量低温下细碳纤维复合材料热导率的稳态测试装置,并使用304不锈钢样品进行了校准。使用测试设备,对8 K至150 K的单向和多向34-700碳纤维-NCT 301环氧复合材料样品进行热导率测量。在295 K下进行热扩散率测量,然后将其用于计算热导率。对纤维与热流方向成0度,90度和45度取向的单向样品进行了评估。还测量了具有+ -45 / 90/0(3)/ 90 / +-45构型的层压板的样品的热导率。在室温下,0°方向的导热系数是90°方向的导热系数的7倍。对于多方向样品,其导热系数在5.7 K时为0.22 W /(m·K)至2.98 W /(m·K)。数据的总体趋势类似于T-300碳纤维样品的趋势。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号