首页> 外文会议>Industry Applications Conference, 2000. Conference Record of the 2000 IEEE >Mapping deflection coil power loss by use of calorimetric power measuring system
【24h】

Mapping deflection coil power loss by use of calorimetric power measuring system

机译:利用量热功率测量系统测绘偏转线圈的功率损耗

获取原文

摘要

A predictive tool has been developed in order to determine the power losses in deflection coils during the design process. This makes it possible to design and redesign deflection coils with respect to minimising power losses. The power loss model is verified by modelling an existing deflection coil and comparing the calculated results with measurements using a calorimetric measuring system. Both the power predictive tool and the calorimetric measuring system are developed at Aalborg University, Institute of Energy Technology, Denmark.
机译:为了确定在设计过程中偏转线圈中的功率损耗,已经开发了一种预测工具。这样就可以设计和重新设计偏转线圈,以最大程度地降低功率损耗。通过对现有的偏转线圈建模,并将计算的结果与量热测量系统的测量结果进行比较,可以验证功率损耗模型。功率预测工具和量热测量系统均由丹麦奥尔堡大学能源技术研究所开发。