【24h】

A new method of noninvasively measuring bladder leak point pressure in female rats

机译:一种无创测量雌性大鼠膀胱漏点压力的新方法

获取原文

摘要

Stress urinary incontinence is diagnosed by decreased leak point pressure (LPP), the bladder pressure at which urine leaks from the bladder. The authors have developed a method to measure LPP in animals. The purpose of this project is to test a device for noninvasive measurement of LPP against the authors' standard invasive method of LPP testing in rats. Four female rats underwent suprapubic bladder catheter implantation. Two days later, the bladder was filled with saline to 1/2 capacity. Pressure was applied to the abdomen while bladder pressure was measured. Pressure was increased until saline leaked from the urethra, to measure LPP. A platform on a force transducer allowed the authors to measure the externally applied force. The study was repeated with the platform of the device over the abdomen. The force was increased until saline leakage occurred. When abdominal pressure was increased in the absence of the device, bladder pressure increased in 7.2/spl plusmn/1.1s to a LPP of 32.5/spl plusmn/6.7 cmH/sub 2/O, giving an increase in bladder pressure of 27.2/spl plusmn/7.3 cmH/sub 2/O from baseline. These values were not significantly different from the duration (5.2/spl plusmn/0.7s), LPP (42.2/spl plusmn/10.6 cmH/sub 2/O), or increase in bladder pressure (30.1/spl plusmn/12.5 cmH/sub 2/O) measured when both force and pressure were recorded, indicating repeatability of the experiment. A linear regression fit to bladder pressure v. force data demonstrated linearity in most cases. Thus, the authors have demonstrated ease of use, repeatability, and reliability of a new device for noninvasively measuring leak point pressure in laboratory rats.
机译:压力性尿失禁是通过降低的漏点压力(LPP)来诊断的,漏点压力是尿液从膀胱漏出时的膀胱压力。作者已经开发出一种测量动物中LPP的方法。该项目的目的是根据作者在大鼠中进行LPP测试的标准侵入性方法来测试用于LPP的非侵入性测量的设备。四只雌性大鼠进行耻骨上膀胱导管植入。两天后,膀胱充满生理盐水至1/2容量。在测量膀胱压力的同时对腹部施加压力。升高压力直至盐水从尿道漏出,以测量LPP。力传感器上的平台允许作者测量外部施加的力。用腹部上方的器械平台重复该研究。力增加直到发生盐水泄漏。在没有设备的情况下增加腹部压力时,膀胱压力以7.2 / spl plusmn / 1.1s升高至LPP为32.5 / spl plusmn / 6.7 cmH / sub 2 / O,从而使膀胱压力增加27.2 / spl比基线高/7.3 cmH / sub 2 / O。这些值与持续时间(5.2 / spl plusmn / 0.7s),LPP(42.2 / spl plusmn / 10.6 cmH / sub 2 / O)或膀胱压力升高(30.1 / spl plusmn / 12.5 cmH / sub)并无显着差异。记录力和压力时测量的2 / O),表明实验的可重复性。在大多数情况下,对膀胱压力与力量数据的线性回归拟合显示出线性关系。因此,作者已经证明了一种新设备的易用性,可重复性和可靠性,该新设备可无创地测量实验室大鼠的泄漏点压力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号