首页> 外文会议>Conference on thermosense >Characterization of an Infrared Spectrograph for Non-Contact Thermometry Applications Using a Sodium Heat Pipe Blackbody
【24h】

Characterization of an Infrared Spectrograph for Non-Contact Thermometry Applications Using a Sodium Heat Pipe Blackbody

机译:使用钠热管黑体的非接触式温度应用红外光谱仪的表征

获取原文

摘要

A two-dimensional imaging spectrograph, developed for non-intrusive temperature measurements in flames, has been characterized using a pressure-controlled sodium heat pipe blackbody (Na-HPBB). The spectrograph contains a two-dimensional PtSi CCD array and provides spatial information in one dimension and spectral information in the other dimension. The usable range of the spectrograph, which images a line approximately 35 mm in length, covers the region from 2.5 mu m to 5.0 mu m. Using the stable and uniform Na-HPBB, the spectrograph was calibrated for absolute spectral radiance by employing Planck's Law. These measurements show that the spectrograph uniformity is within 0.26 percent (k = 2), and provide calibration constants that can be applied to future measurements. The results presented here will enable the spectrograph to be used to measure the emission characteristics of high temperature surfaces, gases, and particles, and as a transfer detector to calibrate other secondary sources.
机译:使用压力控制的钠热管黑体(NA-HPBB)表征了用于在火焰中开发的用于非侵入式温度测量的二维成像光谱仪。光谱仪包含二维PTSI CCD阵列,并在一个维度中提供空间信息和另一个维度的光谱信息。光谱仪的可用范围,其长度约为35毫米的线,覆盖从2.5 mu m到5.0 mu m的区域。使用稳定和均匀的NA-HPBB,通过采用Planck的法律,校准光谱仪的绝对光谱辐射。这些测量表明,光谱仪均匀性在0.26%以内(k = 2),并提供可应用于未来测量的校准常数。这里提出的结果将用于测量高温表面,气体和颗粒的排放特性,以及作为转移检测器来校准其他二级来源的传递探测器。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号