Airtightness of buildings in the artic circle housing fair, Rovaniemi Finland

机译:北极圈住房博览会的建筑物的气密性,Rovaniemi芬兰

获取原文

摘要

Air leak through the external envelope lead to many inconveniences. Higher consumption of heating energy, draught and possible moisture defects are the result of air infiltration. The automatic ventilation system of the house can also be thrown off balance. The factors mentioned above together with poor knowledge of airtightness of houses was reason to start this project airtightness of the buildings in the artic circle housing fair in Rovaniemi, Finland. The airtightness of houses measured by using the fan pressurization method, according to international standard ISO DIS 9972. The fan pressurization method means that in building caused negative air-pressure from normal approximately 0 Pa up to 50 Pa over the buildings envelope. The air leakage points are search by using thermal camera. In this project made research differences between materials, structures and production styles. The method and equipment for measuring airtightness are tested and developed in project.
机译:通过外部信封泄漏导致许多不便。加热能量,草案和可能的水分缺陷的较高消耗是空气渗透的结果。房屋的自动通风系统也可以抛出平衡。以上提到的因素与房屋气密性差的知识相同,是在芬兰罗瓦涅利的艺术圈房展览会中开始这一项目的理由。根据国际标准ISO DIS 9972,使用风扇加压方法测量的房屋的气密性。风扇加压方法意味着在建筑物上,在建筑物包络上的正常空气压力造成的负压。空气泄漏点是使用热摄像头进行搜索的。在该项目中,材料,结构和生产风格之间的研究差异。在项目中测试和开发用于测量气密性的方法和设备。