A typical coil failure in the generator stator is a problem that can usually be fixed with minimum downtime and cost. However, multiple coil failures in a multi turn widning require extensive down times and usually require the expedited manufacture of more coils. Almost always these failures occur when there is excess water that must by bypassed. Invaiably the question the owner always asks is what repairs can be made to the generator in order to operate until a permanent repair can be made or the generator stator can be rewound? This paper focuses on a generato failure and the operation of the generator for four months with 25percent of the generator cut out until it could be rewound.
机译:发电机定子中典型的线圈故障是一个问题,通常可以通过最少的停机时间和最低的成本来解决。但是,多匝焊接中的多个线圈故障需要大量的停机时间,并且通常需要加快制造更多线圈的速度。这些故障几乎总是发生在必须绕开多余的水时。毫无疑问,车主总是问:在进行永久性修理或将发电机定子重绕之前,可以对发电机进行哪些修理才能运行?本文着眼于发电机故障,发电机运转四个月,其中25%的发电机被切断,直到可以倒转为止。