The Superconducting QUantum Interference Device (SQUID) magnetometer can non-invasively detect the magnetic fields created by the Basic Electrical Rhythm (BER) of the Gastrointestinal Tract (GIT). Using anesthetized adult male New Zealand rabbits the authors recorded signals from two isolated bowel segments at the same time, before and after ischemia was induced in either one or both bowel segments. The dominant frequency peaks for each period of recording were determined using autoregressive (AR) spectral analysis. There was a significant fall in the BER frequency in the ischemic segment from 11.8/spl plusmn/0.9 to 7.8/spl plusmn/0.6 cycles per minute (cpm), while there was no change in the normal bowel. It was possible for two observers (LAB, WOR) who were blinded to the preparation, to identify which bowel segment was ischemic. The results of this experiment demonstrate the ability of the SQUID magnetometer to noninvasively detect and differentiate signals from normal and ischemic bowel sources.
机译:超导量子干扰设备(SQUID)磁力计可以无创地检测由胃肠道(GIT)的基本电节律(BER)产生的磁场。作者使用麻醉的成年雄性新西兰兔,在一个或两个肠段引起局部缺血之前和之后,同时记录了两个分离的肠段的信号。使用自回归(AR)频谱分析确定每个记录周期的主频率峰值。缺血段的BER频率显着下降,从每分钟11.8 / spl plusmn / 0.9降至7.8 / spl plusmn / 0.6周(cpm),而正常肠则无变化。对准备工作不知情的两名观察员(LAB,WOR)可能会识别出哪个肠段是缺血性的。该实验的结果证明了SQUID磁力计能够无创地检测和区分正常和缺血性肠源的信号。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号