首页> 外文会议>Current Developments in Optical Design and Engineering VI >Thermal infrared radiometer scan mirror optical performance
【24h】

Thermal infrared radiometer scan mirror optical performance

机译:热红外辐射计扫描镜的光学性能

获取原文

摘要

Abstract: The optical design, test, and fabrication of a large ultra lightweight flat beryllium scan mirror is reported. The mirror is a key component for the (TIR) thermal infrared radiometer instrument which is scheduled to compliment the (EOS) Earth observation satellite program. The unique optical design properties of the mirror provide state of the art performance for scan operations and thermal imaging of the earth's surface in the 8.0 to 12.0 micron wavelength range. The mirror's opto-mechanical design provides a very stable non-deformed platform for the scan drive system. The mirror's optical figure, surface characteristics and protected gold coating have been tested and are well within the flight specifications. !1
机译:摘要:报道了一种大型超轻型铍铍扫描镜的光学设计,测试和制造。镜子是(TIR)热红外辐射计仪器的关键组件,该仪器计划补充(EOS)地球观测卫星计划。反射镜的独特光学设计特性为8.0至12.0微米波长范围内的地球表面进行扫描操作和热成像提供了最先进的性能。反射镜的光机械设计为扫描驱动系统提供了非常稳定的不变形平台。镜子的光学特性,表面特性和镀金涂层均经过测试,完全符合飞行规范。 !1