【24h】

Generalized harmonic loss curves of AC motors fed from two and three level inverters

机译:两级和三级逆变器馈电的交流电动机的广义谐波损耗曲线

获取原文

摘要

Optimized and different sinusoidal PWM methods without and with the addition of different zero-sequence harmonics are generally investigated and compared for both two and three level inverters. The paper examines these PWM techniques from the point of view of the AC motor harmonic losses on the basis of the generalized curves, which are independent of the commutation frequency of the inverter. It is shown that these curves can be given only for the limited region of the fundamental voltage. The accuracy of these curves will be better than 1% if the frequency of the carrier wave is at least forty (without a third harmonic addition) or fifty (with a third harmonic addition) times higher than the fundamental frequency. The comparison of the optimized and the sinusoidal PWM methods show that for the bipolar and dipolar modulations the motor harmonic losses will be 20-30% higher, for the unipolar modulations by several times more than for the optimized method. For unipolar modulation the better results can be obtained by using the three symmetrically shifted carrier waves.
机译:对于两级和三级逆变器,通常会研究并比较优化的和不同的正弦波PWM方法,这些方法不使用和添加不同的零序谐波。本文基于广义曲线从交流电动机谐波损耗的角度研究了这些PWM技术,这些曲线与逆变器的换向频率无关。结果表明,这些曲线只能在基本电压的有限区域内给出。如果载波频率比基本频率高至少四十倍(不加三次谐波)或五十倍(不加三次谐波),则这些曲线的精度将优于1%。优化方法与正弦波PWM方法的比较表明,对于双极性和双极性调制,电动机谐波损耗将比优化方法高20-30%,而对于单极性调制,电动机的谐波损耗要高出几倍。对于单极调制,通过使用三个对称移位的载波可以获得更好的结果。