This paper describes the theoretical equation for residual voltage and the relationship between irradiation dose and residual voltage for electric power cable used in a nuclear power generating station. At first, assuming that the depolarization has a distribution in relaxation time which obey the Cole-Cole equation, we can derive the equation for the residual voltage. From theoretical and experimental investigation it is found that the residual voltage is not influenced by cable length. This is important merit of the residual voltage as the nondestructive diagnosis. When irradiation dose is more than 500 kGy, the residual voltage exhibits a peak. As the dose is increased, the peak moves to the shorter time region. We will discuss the relation between the movement of peak and the resistance of insulating materials.
机译:本文描述了用于核电站的电力电缆的残余电压的理论公式以及辐照剂量与残余电压之间的关系。首先,假设去极化具有弛豫时间的分布且服从Cole-Cole方程,则可以推导剩余电压的方程。从理论和实验研究发现,残余电压不受电缆长度的影响。这是残余电压作为无损诊断的重要优点。当照射剂量大于500kGy时,残余电压显示出峰值。随着剂量增加,峰移至较短的时间区域。我们将讨论峰值运动与绝缘材料电阻之间的关系。