摘要

The problem of vortex meter optimization is considered. A new approach relies on optimization of the whole meter configuration, i.e., the bluff body geometry and the sensor location. Linearity of the meter characteristic, quality of the signal and stability of the signal period were applied as optimization criteria. The dependence of the parameters on the configuration of the meter was confirmed during the tests.
机译:考虑了涡流计优化的问题。一种新方法依赖于对整个电表配置的优化,即钝体几何形状和传感器位置。仪表特性的线性,信号质量和信号周期的稳定性被用作优化标准。在测试过程中确认了参数对电表配置的依赖性。