The most commonly used criteria for PDIV (partial-discharge inception voltage) determination are examined using three synthetic transformer oils as test fluids. It is shown that the PD amplitude distribution changes both with increasing applied voltage and with test duration. The use of a multichannel analyzer was shown to be most helpful in rendering the PDIV statistically more meaningful. It is noted that both the number and amplitude of PDs are random phenomena the occurrence of which is hard to predict. Close to the breakdown voltage the PD activity increases and its amplitude spectrum approaches a quasi-exponential shape.
机译:使用三种合成变压器油作为测试液,检查最常用的PDIV(局部放电起始电压)确定标准。结果表明,PD幅值分布随施加电压的增加和测试持续时间的变化而变化。事实证明,使用多通道分析仪对PDIV的统计意义更为明显。注意,PD的数量和幅度都是随机现象,其发生难以预测。接近击穿电压,PD活性增加,其幅值谱接近准指数形状。