A multichannel numerical system for the measurement of partial discharges (PDs) has been developed in order to improve the ability to identify PD sources and to seek novel criteria for PD harmfulness. This numerical partial discharge analysis system, which associates real-time acquisition and offline processing of results, allows a more refined identification of discharge sources and provide access to harmfulness criteria through numerical calculations on the recorded data. This system is being used during the testing of the following equipment or large-scale representative models: large alternators, HV and MV switchgear, transformers, and onboard power electronic systems.
机译:为了提高识别PD来源的能力并寻求PD有害性的新标准,已经开发了一种用于测量局部放电(PD)的多通道数值系统。该数字局部放电分析系统结合了结果的实时采集和离线处理,可以更精确地识别排放源,并通过对记录的数据进行数值计算来获取有害性标准。该系统正在以下设备或大型代表性型号的测试中使用:大型交流发电机,高压和中压开关柜,变压器和车载电力电子系统。