首页> 外文会议>International symposium on heating, ventilating and air conditioning >RESEARCH ON COOLING LOAD OF TYPICAL COMMERCIAL OFFICE BUILDINGS IN BEIJING AND HONG KONG
【24h】

RESEARCH ON COOLING LOAD OF TYPICAL COMMERCIAL OFFICE BUILDINGS IN BEIJING AND HONG KONG

机译:北京和香港典型商业办公建筑的冷却负荷研究。

获取原文

摘要

How different design and operation manners influence the cooling load level quantitatively was studied in two buildings located in Beijing and Hong Kong. Field investigations and simulations were conducted to understand the causes of building cooling loads. Then the influence of different climates was eliminated to highlight the influences of different design and operation manners. On the basis of Beijing Building, the design and operation manners were changed into the Hong Kong Building mode successively. Three most important factors that cause huge differences on the cooling loads were found: air conditioning hours, indoor air conditioning temperature and lighting & plug electricity heat gain. Suggestions for the reasonable manners of design and operation were provided.
机译:在北京和香港的两座建筑物中,研究了不同的设计和运行方式如何定量地影响制冷负荷水平。进行了现场调查和模拟,以了解建筑物冷却负荷的原因。然后消除了不同气候的影响,突出了不同设计和操作方式的影响。在北京大厦的基础上,设计和运营方式相继转变为香港大厦模式。发现导致制冷负荷差异巨大的三个最重要的因素:空调小时数,室内空调温度以及照明和插头电的热量获取。提供了合理的设计和操作方式的建议。