According to the requirements of design and construction rules for mechanical components of pressurized water reactor nuclear islands, the primary hydrostatic test must be carried out before and after the operation of nuclear power plant. The overpressure protection system is used to prevent the accidental overpressure of the primary circuit during the hydrostatic test, and to alleviate the serious consequences of overpressure on the involved test equipment. The system design and equipment selection for the primary circuit of the third generation nuclear power plants are much different from that of the second generation ones. In addition, the construction of the third generation nuclear power plants is too late to have the reference experience. Based on the control characteristics of the primary process system in European pressurized water reactor and the deficiency of the overpressure protection system in china pressurized water reactor, the research work is conducted from the hereafter aspects, the pressure control strategy of the primary hydrostatic test, scheme design of the overpressure protection system, commissioning and site application. And it is also applied in the primary hydrostatic test of a nuclear power plant. The practical results show that the implementation principle of the overpressure protection system is correct, the analysis of risks and various countermeasures is appropriate, and the implementation scheme is feasible. The research work and practice can provide some reference for the subsequent project construction.
机译:根据压水堆核岛机械部件设计和建造规则的要求,必须在核电厂运行之前和之后进行一次水压试验。过压保护系统用于防止在静水压测试过程中一次回路的意外过压,并减轻过压对所涉及的测试设备造成的严重后果。第三代核电厂的一次电路的系统设计和设备选择与第二代核电厂的系统设计和设备选择有很大不同。此外,第三代核电站的建设还为时过晚,无法获得参考经验。针对欧洲压水堆一级工艺系统的控制特点,结合我国压水堆超压保护系统的不足,从以下几个方面进行了研究工作,一次水压试验的压力控制策略,方案。超压保护系统的设计,调试和现场应用。它也被应用在核电站的一次静水压试验中。实际结果表明,该超压保护系统的实施原理是正确的,对风险和各种对策的分析是适当的,实施方案是可行的。研究工作和实践可为后续项目建设提供参考。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号