首页> 外文会议>IEEE Applied Power Electronics Conference and Exposition >Power Cycling of Three-Level Inverters for Low Speed Operation
【24h】

Power Cycling of Three-Level Inverters for Low Speed Operation

机译:低速运行的三电平逆变器的功率循环

获取原文

摘要

Low speed operation of inverters can cause high maximum temperature that results in the necessity of over rating design of power modules. Operating the converter in fundamental frequencies higher than zero can have worse results than the DC output due of the high temperature ripple. Temperature ripple can stress the bond wires and chips. This paper investigates the possibility of using different topologies (two- level and three-level) and semiconductor types for lowering losses and distributing the losses between the power semiconductors.
机译:逆变器的低速运行会导致最高温度升高,从而导致功率模块的超额设计必不可少。由于高温纹波,以高于零的基频运行转换器可能会产生比直流输出更差的结果。温度波动会给键合线和芯片造成压力。本文研究了使用不同拓扑结构(两级和三级)和半导体类型来降低损耗并在功率半导体之间分配损耗的可能性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号