首页> 外文会议>IEEE PES Asia-Pacific Power and Energy Engineering Conference >A Novel Directional Relay Applicable to Power System With Wind Farms
【24h】

A Novel Directional Relay Applicable to Power System With Wind Farms

机译:一种适用于带风电场电力系统的新型方向继电器

获取原文

摘要

A novel directional relay in time domain is proposed in the paper and can be used in the transmission line for wind power integration. Firstly, the models of grounding fault and non-grounding fault in the forward and reverse side of relay location are established, respectively. As for a forward non-grounding fault, the current and voltage of fault phases satisfies a module with positive resistance and positive inductance. As for a forward grounding fault, the zero module current and voltage measured at the relay location satisfies a model with negative resistance and negative inductance model in the zero module net. Then, the forward fault model conformity is defined on the basis of correlation analysis theory. Using the resistance and inductance calculated based on least square method, the forward fault model conformity is almost equal to 1 for a forward fault and -1 for a reverse fault. Thus, the fault direction can be identified by model recognition. Eventually, the effectiveness of the proposed scheme is verified by simulation in PSCAD.
机译:在纸上提出了一种新的时域中的方向继电器,可用于风力电力集成的传输线。首先,分别建立了继电器位置的前向和反面中的接地故障和非接地故障的模型。至于前向非接地故障,故障阶段的电流和电压满足具有正电阻和正电感的模块。至于前进接地故障,在继电器位置测量的零模块电流和电压满足零模块网中具有负电阻和负电感模型的模型。然后,基于相关分析理论来定义前向故障模型符合性。使用基于最小二乘法计算的电阻和电感,前向故障模型符合性几乎等于前向故障的1,以及-1为反向故障。因此,可以通过模型识别来识别故障方向。最终,通过PSCAD的模拟验证了所提出的方案的有效性。