The optimal performance of power grid depends on many factors, and one of which is the reliability of the substation communication network. These substation communication networks are required for real time monitoring and control of the power grid. Power grid operators are always eager to know the behavior of the substation communication network to enable the operators perform real time monitoring and control function of the power grid through the communication network. Substation communication network historical data and real time operating data are vital requirements for effective design of a robust and reliable communication network. These communication networks historical data are also required for predicting future performance of the grid network. This paper has demonstrated the successful use of communication network collected data (that is historical data) to determine the reliability and performance of an IEC 61850 substation communication network. The key findings of this study are that increased data rate of an IEC 61850 based communication network, reduces the network latency and the implementation of network redundancy scheme improved the network reliability. Also, increased data rate and implementation of network redundancy scheme improved the derived communication network reliability averagely by 3.8% over fifteen years period. The derived communication network improved reliability was also found to meets the IEC 61850 transfer time requirements required for performing substation protection, monitoring and control functions.
机译:电网的最佳性能取决于许多因素,其中之一就是变电站通信网络的可靠性。这些变电站通信网络是实时监视和控制电网所必需的。电网运营商始终渴望了解变电站通信网络的行为,以使运营商能够通过通信网络执行电网的实时监视和控制功能。变电站通信网络的历史数据和实时运行数据是有效设计健壮可靠的通信网络的重要要求。这些通信网络的历史数据对于预测网格网络的未来性能也是必需的。本文演示了成功使用通信网络收集的数据(即历史数据)来确定IEC 61850变电站通信网络的可靠性和性能。这项研究的主要发现是,提高了基于IEC 61850的通信网络的数据速率,减少了网络等待时间,并且网络冗余方案的实施提高了网络的可靠性。而且,随着数据速率的提高和网络冗余方案的实施,在过去的15年中,平均推导的通信网络可靠性提高了3.8%。还发现派生的通信网络具有更高的可靠性,可以满足执行变电站保护,监视和控制功能所需的IEC 61850传输时间要求。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号