In this work, a novel method for choosing a global set of preventive controls for voltage stability analysis is developed. The method depends on top-down and bottom-up approaches to obtain the set of controls according to voltage stability sensitivity analysis. At first, the sensitivities of the voltage stability margins of network buses to preventive controls are obtained. The average of the sensitivities referred to each preventive control is then calculated, which gives an indicator about how each preventive control can improve the voltage stability margin of power system. The average is done over the sensitivities of different critical buses located at different locations. The two approaches (top-down and bottom-up) are then performed on the averaged sensitivities to choose a set of the most efficient controls. The proposed method is able to simultaneously eliminate the impact of system contingencies on network buses. The proposed method is checked on the IEEE 39 bus network. The results demonstrate the accuracy and the validity of the proposed method for control selection.
机译:在这项工作中,开发了一种新颖的方法,用于选择用于电压稳定性分析的全局预防控制集。该方法依赖于自上而下和自下而上的方法来根据电压稳定性灵敏度分析获得一组控件。首先,获得网络总线的电压稳定裕度对预防性控制的敏感性。然后计算参考每个预防性控制的灵敏度的平均值,这给出了关于每个预防性控制如何可以改善电力系统的电压稳定性裕度的指标。平均值是根据位于不同位置的不同关键总线的敏感度得出的。然后对平均灵敏度执行两种方法(自上而下和自下而上)以选择一组最有效的控件。所提出的方法能够同时消除系统突发事件对网络总线的影响。在IEEE 39总线网络上检查了提出的方法。结果证明了所提出的控制选择方法的准确性和有效性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号