The performance of the standard meter is very important for the automatic verification lines. In order to study the influence of the reference conditions of the automatic verification lines on the standard meter, the analysis method combining the physical model and the mathematical model is adopted. Firstly, based on the internal structure of the standard meter, the effect of temperature and humidity on voltage/current sampling circuit and signal processing circuit are sequentially analyzed. Then, based on the above influencing factors, the experiment was designed. From the experimental data, the BP neural network was used to model and analyze the standard meter. The validity of the model to the standard meter was verified by the verification of the actual data set. It provides a theoretical basis for the large-scale verification of smart meters.
机译:标准仪表的性能对于自动验证线非常重要。为了研究自动验证线参考条件对标准仪表的影响,采用了物理模型和数学模型相结合的分析方法。首先,根据标准电表的内部结构,依次分析温度和湿度对电压/电流采样电路和信号处理电路的影响。然后,基于上述影响因素,设计了实验。根据实验数据,使用BP神经网络对标准仪表进行建模和分析。通过对实际数据集的验证,验证了该模型对标准仪表的有效性。它为智能电表的大规模验证提供了理论依据。