An increasing number of fire and electric shock accidents in power sector increases the need for high impedance fault (HIF) detection as the existing over-current relay in the system is not able to detect the HIF state. The HIF detector employing sequence components of current along with voltage is proposed in this paper. The proposed HIF detector composed of two components i.e. current HIF detector and voltage HIF detector, in conjunction with existing distribution network set up. The first component analyzes current sequence components when fault appears in the network whereas later analyzes voltage sequence components. The current HIF detector operates when, significant amount of zero and negative sequence components starts appearing in the network. On the other hand, voltage HIF detector assists the current HIF detector in confirming the HIF state by examining the negative voltage sequence component. The performance of combined detector is evaluated by inducing high impedance fault at different nodes on the IEEE-6-bus radial balanced distribution system. The proposed detector makes use of only current and voltage of the system for HIF detection and doesn't require any additional feature extraction phase. The HIF detector in the proposed paper requires only one unit of sequence converter. Now, sequence components coming out from sequence converter are fed to HIF relay logic which is used in conjunction with existing over-current relay. Hence, this detector is cost effective as compared with the different HIF detectors presented in literature. The proposed method is simulated in a simulation environment. This method is fast and reliable as it detects the fault within one cycle.
机译:由于系统中现有的过电流继电器无法检测到HIF状态,越来越多的火力和电力击穿事故增加了对高阻抗断层(HIF)检测的需求。本文提出了采用电流序列分量的HIF检测器以及电压。所提出的HIF检测器由两个组件组成,即电流HIF检测器和电压HIF检测器,与现有的分发网络设置相结合。当在网络中出现故障时,第一组件分析当前序列组件,而后分析电压序列组件。当前的HIF检测器在网络中出现大量零和负序列组件时操作。另一方面,电压HIF检测器通过检查负电压序列组分来帮助电流HIF检测器确认HIF状态。通过在IEEE-6-BUS径向平衡分配系统上诱导不同节点的高阻抗故障来评估组合检测器的性能。所提出的检测器仅利用系统的电流和电压进行HIF检测,并且不需要任何附加特征提取阶段。拟议文件中的HIF检测器只需要一个单位的序列转换器。现在,从序列转换器出来的序列组件被馈送到HIF中继逻辑,其与现有过电流继电器结合使用。因此,与文献中呈现的不同HIF探测器相比,该检测器具有成本效益。所提出的方法在仿真环境中模拟。此方法快速且可靠,因为它在一个周期内检测到故障。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号