This paper shows the practical demonstration of different factors that make it possible to overcome any shortcoming concerning the detection of broken rotor bar fault in the machines using the fault frequency components from the current, flux and instantaneous power signals under different levels of loading. Unlike previous studies that generally used single sensor type to detect broken rotor bar fault using current sensor at full-load conditions, or limited number of load cases, this research examines the use of multiple type sensors i.e. current, voltage, axial flux and instantaneous power to detect the broken rotor bar fault using standard fault frequencies. This paper also shows the importance to examine the variability in their amplitudes to other effects apart from load and fault severity.
机译:本文显示了不同因素的实际演示,使得可以克服使用来自电流,通量和瞬时功率信号的故障频率分量在机器中检测到机器中的断开转子杆故障的任何缺点。与以前的研究不同,通常使用单传感器类型使用电流传感器在满载条件下使用电流传感器检测破损的转子杆故障,或者负载箱数有限,这项研究检查了多种类型传感器的使用,即电流,电压,轴向通量和瞬时功率使用标准故障频率检测破损的转子杆故障。本文还表明了将其幅度与其他效果与负载和故障严重相比的其他效果的变异性的重要性。