首页> 外文会议>IEEE International Symposium on Computer-Based Medical Systems >Analysing the Performance of a Real-Time Healthcare 4.0 System using Shared Frailty Time to Event Models
【24h】

Analysing the Performance of a Real-Time Healthcare 4.0 System using Shared Frailty Time to Event Models

机译:使用脆弱事件时间共享模型分析实时Healthcare 4.0系统的性能

获取原文

摘要

This paper introduces the real-time Healthcare 4.0 system, the VILIAlert system and a new approach that we propose for the robust assessment of it's performance. The VILIAlert system alerts clinicians when a patient's tidal volume value rises above the clinically accepted level of 8 ml/kg as beyond this point (> 8 ml/kg), a patient is considered high risk of permanent damage to their lungs. In order to ensure success with the VILIAlert system, the ideal scenario is to ensure that as soon as patients in the Intensive Care Unit experience tidal volume values beyond the 8 ml/kg level, a clinical intervention can be carried out so to minimise the risk of patients ever having permanent damage. The approach has been implemented in the Intensive Care Unit at the Royal Victoria Hospital Belfast, Northern Ireland demonstrating the potential for such an approach to be used across all hospitals in the region.
机译:本文介绍了实时Healthcare 4.0系统,VILIAlert系统以及我们提出的用于对其性能进行可靠评估的新方法。当患者的潮气量值超出此点(> 8 ml / kg)的临床可接受水平(> 8 ml / kg)时,VILIAlert系统会向临床医生发出警报,认为该患者存在永久性损害其肺部的高风险。为了确保VILIAlert系统的成功,理想的方案是确保重症监护病房的潮气量值一旦超过8 ml / kg,就可以进行临床干预以最大程度地降低风险曾经遭受永久性损害的患者。该方法已在北爱尔兰贝尔法斯特皇家维多利亚医院的重症监护室实施,表明该方法可在该地区所有医院中使用。